Monday 31 May 2021

Everything You Need to Know About Contactors

Through contacts whenever a relay is used to switch a large amount of electrical power, it is designated by a special name: ac contactors. Contactors generally have multiple contacts, and those contacts are usually open so that when the coil is de-energized power to the load is shut off.

Control of electric motors is the most common industrial use for contactors

The respective phases of the incoming 3-phase AC power; typically at least 480 Volts for motors 1 horsepower or great are switched by the top three contacts. An auxiliary contact is the lowest contact which when compared to the large motor power contacts has a current rating much lower, but like power, contacts are actuated by the same armature.

central air contactor

In a relay logic circuit the auxiliary contact is frequently used, or for another part of the motor control scheme, typically switching 120 Volt AC power instead of the motor voltage. One central air contactor may have There are several auxiliary contacts in one contactor, either normally open or normally closed if required.

Three-Phase Electric Motor Contactor

For a three-phase electric motor here is a contractor that at a municipal water treatment plant is installed on a panel as part of an electrical control system:

Sample Contactors

At the top of the split ac contactor that too with the help of screw terminals labeled L1, L2, and L3, three-phase, 480 volt AC power comes into the three normally-open contacts. At the bottom of this device via screw terminals labeled T1, T2, and T3, power to the motor exits the overload heater assembly.

The overload heater units are generally black, square-shaped blocks with the label W34. For a certain horsepower and temperature rating of the electric motor, it indicates a particular thermal response.

central air contactor

The overload heater units must be replaced with units having a thermal response suitable for the new motor only when an electric motor of differing power or temperature ratings. On the appropriate heater units that need to be used, the motor manufacturer can provide information. 

In manually resetting the normally-closed switch contact back to its normal state a white push-button located between the T1 and T2 line heaters is used. Follow us on Facebook

Saturday 8 May 2021

How a Watt Meter can Help in Reducing Electricity Bills

For many decades electricity meters are around. The electrical consumption is measured by an electricity meter and it displays it on the screen. But we are very much used to the electricity portable kWh meter that measures the total electricity consumption of the entire house or office.

digital kWh meter

What is a Kill a Watt meter?

Measuring the consumption of electricity of the appliance directly connected to it, A Kill a Watt meter is a device. It is originally called a Kilowatt meter. It has an LCD that shows various readings like power factor, reactive power, current, true power, apparent power, voltage, energy consumed in kWh for the connected appliance. About the number of units consumed, some models also display estimated costs.

How to Use a Kill a Wattmeter

It is very simple to use a Kill a Wattmeter. In the line between the power supply and the appliance (of which you want to measure the electricity consumption), it needs to be installed there.

digital kWh meter

If you want to measure the electricity consumption of your refrigerator then unplug the power cable of the refrigerator from the power source and plug it in the port in the digital kWh meter. Now in the PowerPoint plug, this Kill a Wattmeter.

Leave it in that particular condition for a few days (or hours, whichever is suitable to you) and after that, you will observe that there is a reading on the LCD screen of the Kill a Wattmeter.

digital kWh meter

Models of Kill a Wattmeters

You will find kill a Watt meter in different variants. Although across all the meters the basic functionality remains the same few additional features are added in different variants. You must have some idea about them. Hence, these are few points for your knowledge:

  • P4460 Kill a Watt EZ: The major shortcoming of a socket mounted kWh meter is that it cannot store information. To overcome this situation, this particular model includes a backup battery which helps in storing the information after it is disconnected from the power supply.
  • P4400: It is the first and the most basic version of Kill a Wattmeter. Follow us on Twitter

A Deep Insight about Moulded Case Circuit Breakers

There is a guardian in the complex world of electrical systems, where everything from the tiniest device to the biggest plant is powered by ...